What is the difference between DF1B-**P-2.5***(Discontinued), DF1B-**P-2.5***(01) and DF1B-**P-2.5***(28)(Discontinued)?** stands for number of contacts. *** stands for contact style.

Modified on Fri, Jun 26 at 12:46 PM

​The difference is plating of contact area, RoHS and reinforced lock.
DF1B-**P-2.5*** : Tin, non RoHS, discontinued
DF1B-**P-2.5***(01) : 0.2 μ gold, RoHS2
DF1B-**P-2.5***(28) : 0.2 μ gold, RoHS2, reinforced lock, discontinued.
Replacement of DF1B-**P-2.5*** is DF1BZ-**P-2.5*** that is tin plated contact and complies with RoHS2.